The short version of Electrospray ionization fits in a sentence. The long version — which is the one that helps — is below.
This page was last updated on 2025-12-27 and is reviewed periodically as new material appears.
Common degradation pathways include oxidation of the methionine side chain, hydrolysis of the peptide backbone, and aggregation under unfavourable pH or concentration. Stability studies typically monitor the main peak by chromatography and report total related substances as a percentage. Because no official monograph exists, acceptance criteria vary between laboratories, and reported purity values are not directly comparable across suppliers. Analysts therefore document the method, column, and detection wavelength alongside each result, and open questions remain about how much biological activity the oxidised forms retain.
Solid semax is typically supplied as a lyophilised powder that is hygroscopic and sensitive to moisture, light, and repeated temperature cycling. Long-term storage of the dry peptide is generally recommended at approximately -20 degrees Celsius, while shorter working periods may use refrigeration at 2 to 8 degrees Celsius. Vials should remain tightly closed and desiccated when brought to room temperature, because condensation can damage the material before it is weighed. Dividing a batch into aliquots is preferable to thawing one container repeatedly.
The proposed mechanism centres on neurotrophic signalling rather than direct receptor activation. Semax is reported to increase expression of brain-derived neurotrophic factor and nerve growth factor in several brain regions, and to shift the balance between excitatory and inhibitory neurotransmitter systems. Interaction with melanocortin receptors has been suggested because of the parent ACTH fragment. Many of these findings come from rodent studies, and the extent to which they translate to human physiology remains an open question.
Scientific literature on semax is unevenly distributed. A substantial share of published work originates from a small number of laboratories in Russia, while independent replication elsewhere is limited. Human data consist mostly of small trials with short follow-up, and several reported outcomes rely on subjective rating scales. Questions about how much intact peptide reaches the central nervous system after nasal administration, and how long it persists there, are still unresolved. The compound is best described as an active research subject rather than a settled pharmacological agent.
Semax is a synthetic heptapeptide with the sequence Met-Glu-His-Phe-Pro-Gly-Pro. It was derived from the ACTH(4-10) fragment, a short segment of adrenocorticotropic hormone that lacks the hormonal activity associated with the full-length peptide. Researchers at the Institute of Molecular Genetics in Moscow developed the compound during the 1980s. It has been registered as a pharmaceutical product in Russia and several neighbouring countries, where it is supplied as a nasal solution, and it is also sold internationally as a research chemical.
| Property | Value | Notes |
|---|---|---|
| Typical analytical method | Reversed-phase HPLC with UV detection | Separates target peptide from truncated and oxidised forms |
| Identity confirmation | LC-MS or ESI-MS | Compares observed and calculated molecular ion |
| Primary degradation route | Methionine oxidation | Forms the sulfoxide; monitored as an early-eluting peak |
| Short-term storage | 2 to 8 degrees Celsius | Applies to working vials and reconstituted portions |
| Common synonyms | ACTH(4–10) analogue, MEHFPGP | Descriptive names used in laboratory catalogues |
Identity and purity of Semax are established mainly by reversed-phase high-performance liquid chromatography coupled with mass spectrometry. The chromatographic trace gives a purity estimate as a percentage of total peak area, while electrospray or matrix-assisted laser desorption ionization confirms the molecular mass against the calculated value. Amino acid analysis and sequence-specific fragmentation provide further confirmation when a supplier's chain of custody is unclear. Vendors frequently quote a purity figure without stating the detection wavelength or the integration method, which limits how far one number can be compared with another.
Stability depends heavily on physical state. Lyophilized powder held dry, cold and dark retains its content over long periods, whereas dissolved peptide begins to change within days at room temperature. The most cited degradation route is oxidation of the methionine residue, which converts the peptide to a sulfoxide form that elutes differently on chromatography. Hydrolysis of amide bonds and adsorption onto container walls contribute smaller losses. Buffers that exclude oxygen from the headspace slow the oxidation pathway, but no single condition prevents all change indefinitely.
Practical handling follows from those properties. Bulk material is best divided into single-use portions soon after receipt, because each thaw exposes the whole container to moisture and temperature cycling. Vials should be allowed to reach room temperature before opening to prevent condensation on the powder. Low-binding plasticware reduces loss of dilute solutions, and sterile filtration is used when a preparation must remain free of microbial growth. Records of batch number, reconstitution date and storage history are what allow a later analytical result to be interpreted meaningfully.
Semax is a synthetic heptapeptide with the sequence Met-Glu-His-Phe-Pro-Gly-Pro. Its design combines the ACTH(4-7) core fragment with a C-terminal Pro-Gly-Pro extension, a modification intended to improve stability and prolong activity. The molecule is hydrophilic, carries no lipid chains or glycosylation, and has a theoretical mass just over 810 daltons in its free form. All seven residues are proteinogenic amino acids, so no non-natural building blocks appear in the backbone. A free N-terminal methionine and C-terminal proline define the unmodified parent peptide.
The compound was developed during the 1980s at the Institute of Molecular Genetics in Moscow as part of research on fragments of adrenocorticotropic hormone. Early work examined short ACTH-derived sequences that retained neurotrophic effects while lacking the endocrine activity of the full hormone. Semax entered clinical use in Russia during the 1990s, where it received registration for several neurological indications. Outside that region it remained primarily a laboratory research material rather than an approved therapeutic. English-language literature on it grew more slowly and frequently cited the original Russian studies.
Terminology around the compound varies by source. It appears in catalogues and papers as Semax, as the heptapeptide ACTH(4-7)-Pro-Gly-Pro, and under various alphanumeric laboratory codes used by individual suppliers. These names refer to the same sequence but may imply different salt forms, purity grades, or counter-ions. Peptide databases usually list the free base mass, while product descriptions sometimes report acetate or trifluoroacetate salts with a different formula weight. Because naming conventions for research peptides are not standardised across vendors, checking the declared sequence and measured mass is more reliable than relying on a trade name alone.
Identity and purity are commonly assessed by reversed-phase high-performance liquid chromatography, with ultraviolet detection near 214 nanometers for the peptide backbone. Mass spectrometry, either electrospray or matrix-assisted laser desorption, confirms molecular mass and detects truncation or modification products. Amino acid analysis can verify composition. Because the sequence contains no strongly absorbing aromatic residue apart from phenylalanine, detection wavelengths are chosen carefully. Purity values above 95 percent are typical for research-grade material.
Quality documentation for research-grade peptide usually includes a certificate of analysis stating purity, identity, and residual counterion content. Batch-to-batch variation in purity and salt form is a recognized issue, and comparisons across suppliers require attention to the exact counterion, for example acetate versus trifluoroacetate. Sequence verification by tandem mass spectrometry provides stronger evidence than a single mass measurement. For any study reporting biological results, the analytical method and the measured purity should be stated explicitly. Independent verification of supplier claims is considered good practice.
各国监管态度分化明显。俄罗斯按处方药管理,部分东欧国家留有使用记录;欧盟与美国未批准其作为药物上市,市面流通品通常标注为研究用化学品。身份差异意味着标示含量、纯度与无菌性缺少统一核查。体育领域还牵涉反兴奋剂名录,跨境携带则受目的地药品法规约束。
Semax 是人工设计的七肽,序列为 Met-Glu-His-Phe-Pro-Gly-Pro,骨架取自促肾上腺皮质激素片段 ACTH(4-10)。它于二十世纪八十年代在苏联的分子遗传学研究机构内合成。设计目标是保留该片段与注意力和记忆相关的活性,同时剔除促皮质激素释放等内分泌作用。此后俄罗斯将其登记为药品并进入临床使用。
当时的短肽研究普遍关注能否穿越血脑屏障、在低剂量下产生中枢效应,Semax 属于这一路线。鼻内给药是其主要使用方式,俄语文献报道的适应症涵盖缺血性卒中、短暂性脑缺血发作、认知功能减退以及视神经病变。这些研究大多发表在当地期刊上,样本规模与终点设置同西方试验惯例存在差异,国际同行对其临床证据的强度看法不一。
== History == In 1840 the Colonial Office was given the authority to divide New Zealand into counties, hundreds, towns, townships, and parishes. These divisions were to be of set sizes (similar to North American divisions, many of which are rectangular in shape) but this was rarely implemented.
== Research == It is under development by Cara Therapeutics as an intravenous agent for the treatment of postoperative pain. An oral formulation has also been developed. Due to its peripheral selectivity, difelikefalin lacks the central side effects like sedation, dysphoria, and hallucinations of previous KOR-acting analgesics such as pentazocine and phenazocine. In addition to use as an analgesic, difelikefalin is also being investigated for the treatment of pruritus (itching). Difelikefalin has completed phase II clinical trials for postoperative pain and has demonstrated significant and "robust" clinical efficacy, along with being safe and well tolerated. It has also completed a phase III clinical trial for uremic pruritus in hemodialysis patients.
Smoking is the cause of more than 7 million deaths per year, making it the most common cause of preventable early death. One study found that male and female smokers lose an average of 13 and 15 years of life, respectively, while another measured a loss of life of 7 years. Each cigarette is estimated to shorten life by an average of 11 minutes, though this may vary slightly depending on the contents and brand. More recently, it has been reported to be 20 minutes. At least half of all lifelong smokers die early as a result of smoking. Smokers are three times more likely to die before the age of 70 than non-smokers. In the United States, cigarette smoking and exposure to tobacco smoke account for roughly one in five, or at least 443,000 premature deaths annually. To put this into context, ABC's Peter Jennings (who would later die at 67 from lung cancer caused by life-long smoking) famously reported that in the US alone, smoking tobacco kills the equivalent of three jumbo jets full of people crashing every day, with no survivors. On a worldwide basis, this equates to a single jumbo jet every hour. A 2015 study found that about 17% of mortality due to cigarette smoking in the United States is due to diseases outside of those commonly linked with smoking. Official estimates may therefore be significantly underestimating the number of deaths currently being attributed to smoking. It is estimated that there are between 1 and 1.4 deaths per million cigarettes smoked. Cigarette factories are the most deadly factories in the history of the world.
=== Spectroscopic identification === Typically the presence of an amine functional group is deduced by a combination of techniques, including mass spectrometry as well as NMR and IR spectroscopies. 1H NMR signals for amines disappear upon treatment of the sample with D2O. In their infrared spectrum primary amines exhibit two N–H bands, whereas secondary amines exhibit only one. In their IR spectra, primary and secondary amines exhibit distinctive N–H stretching bands near 3300 cm−1. Somewhat less distinctive are the bands appearing below 1600 cm−1, which are weaker and overlap with C–C and C–H modes. For the case of propylamine, the H–N–H scissor mode appears near 1600 cm−1, the C–N stretch near 1000 cm−1, and the R2N–H bend near 810 cm−1.
Sources: en.wikipedia.org
=== Inert gas === Carbon dioxide is one of the most commonly used compressed gases for pneumatic (pressurized gas) systems in portable pressure tools. Carbon dioxide is also used as an atmosphere for welding, although in the welding arc, it reacts to oxidize most metals. Use in the automotive industry is common despite significant evidence that welds made in carbon dioxide are more brittle than those made in more inert atmospheres. When used for MIG welding, CO2 use is sometimes referred to as MAG welding, for Metal Active Gas, as CO2 can react at these high temperatures. It tends to produce a hotter puddle than truly inert atmospheres, improving the flow characteristics. Although, this may be due to atmospheric reactions occurring at the puddle site. This is usually the opposite of the desired effect when welding, as it tends to embrittle the site, but may not be a problem for general mild steel welding, where ultimate ductility is not a major concern. Carbon dioxide is used in many consumer products that require pressurized gas because it is inexpensive and nonflammable, and because it undergoes a phase transition from gas to liquid at room temperature at an attainable pressure of approximately 60 bar (870 psi; 59 atm), allowing far more carbon dioxide to fit in a given container than otherwise would. Life jackets often contain canisters of pressured carbon dioxide for quick inflation. Aluminium capsules of CO2 are also sold as supplies of compressed gas for air guns, paintball markers/guns, inflating bicycle tires, and for making carbonated water.
Serine hydroxymethyltransferase can decompose serine into formaldehyde and glycine, according to the reaction HOCH2CH(NH2)CO2H → CH2O + H2C(NH2)CO2H. Methylotrophic microbes convert methanol into formaldehyde and energy via methanol dehydrogenase: `CH3OH → CH2O + 2e− + 2H+ Other routes to formaldehyde include oxidative demethylations, semicarbazide-sensitive amine oxidases, dimethylglycine dehydrogenases, lipid peroxidases, P450 oxidases, and N-methyl group demethylases. Formaldehyde is catabolized by alcohol dehydrogenase ADH5 and aldehyde dehydrogenase ALDH2.
== Structure == cMyBP-C is a 140.5 kDa protein composed of 1273 amino acids. cMyBP-C is a myosin-associated protein that binds at 43 nm intervals along the myosin thick filament backbone, stretching for 200 nm on either side of the M-line within the crossbridge-bearing zone (C-region) of the A band in striated muscle. The approximate stoichiometry of cMyBP-C along the thick filament is 1 per 9-10 myosin molecules, or 37 cMyBP-C molecules per thick filament. In addition to myosin, cMyBP-C also binds titin and actin. The cMyBP-C isoform expressed in cardiac muscle differs from those expressed in slow and fast skeletal muscle (MYBPC1 and MYBPC2, respectively) by three features: (1) an additional immunoglobulin (Ig)-like domain on the N-terminus, (2) a linker region between the second and third Ig domains, and (3) an additional loop in the sixth Ig domain. cMyBP-C appears necessary for normal order, filament length and lattice spacing within the structure of the sarcomere.
Sources: en.wikipedia.org
According to the operators, the MIC tank pressure gauge had been malfunctioning for roughly a week. Other tanks were used, rather than repairing the gauge. The build-up in temperature and pressure is believed to have affected the magnitude of the gas release. UCC admitted in their own investigation report that most of the safety systems were not functioning on the night of 3 December 1984. The design of the MIC plant, following government guidelines, was "Indianized" by UCIL engineers to maximise the use of indigenous materials and products. Mumbai-based Humphreys and Glasgow Consultants Pvt. Ltd., were the main consultants, Larsen & Toubro fabricated the MIC storage tanks, and Taylor of India Ltd. provided the instrumentation. In 1998, during civil action suits in India, it emerged that the plant was not prepared for problems. No action plans had been established to cope with accidents of this magnitude. This included not informing local authorities of the quantities or dangers of chemicals used and manufactured at Bhopal.
The microneedle patch (MNPs) is a type of transdermal patch which retains the advantages, but reduces the disadvantages of basic transdermal patches. Embedding as many as 102–104 needles per square centimetre of patch, encapsulated or coated with intended drug, MNPs can easily pass skin tissue known as the stratum corneum which is roughly 20 μm in thickness, allowing up to the size of macromolecule to pass. MNPs were developed mainly because transdermal patch can deliver smaller size or micronized molecules such as nicotine and birth control which easily diffuse and penetrate the skin, but lack in delivering macro or large size molecules. The 100–1000 μm needles spread across the patch, making sure people will not feel any discomfort from the patch. There are two types of needles used in MNPs, the first one is non-water-soluble needles made out of metal, ceramic, or polymer, and the second one is water-soluble needles made out of saccharides or soluble polymers. MNPs can also be engineered to deliver molecules into other tissues. Some that as of 2018 have been under development include internal surfaces such as the mouth, vagina, gastrointestinal tract, and vascular wall; and external surfaces such as the skin, eyes, fingernails, anus, and scalp.
Although the demand for fine chemicals on the merchant market has not grown to the extent originally anticipated, fine chemicals still provide opportunities for companies, which are fostering certain critical success factors, namely running fine chemicals as a core business, pursuing niche technologies—primarily biotechnology—and taking advantage of the opportunities offered by the Asian market.
Sources: en.wikipedia.org
Dry powder is usually kept at about -20 degrees Celsius for long-term storage and at 2 to 8 degrees Celsius for short working periods. Containers should stay sealed and protected from light and moisture to limit degradation.
Oxidation of the methionine residue to the sulfoxide is a frequently reported change, and it usually appears as an earlier-eluting peak in reversed-phase chromatography. Backbone hydrolysis products can also accumulate in aqueous solution.
Liquid chromatography coupled with mass spectrometry is the usual approach, because the observed molecular ion can be compared with a calculated mass of about 813.9 Da. Retention time alone does not establish identity.
Semax is based on the ACTH(4-10) fragment, a seven-amino-acid segment of adrenocorticotropic hormone. The synthetic peptide retains the core sequence while removing regions associated with endocrine activity. This modification is intended to isolate effects on the nervous system.